PHYSICAL DATA:

Solids: By weight 42.2% / By Volume 51.37%

Cure time at 70F (21C): 2 hours to touch. 

Overcoat with RUSTVACCINE or other coatings immediately after surface is dry to the touch to achieve proper

adhesion. Higher temperatures  will shorten cure times, lower temperatures will slow curing. Can be over coated within1 hour after reaching the dry-to-touch stage

Lead and Chromate free

Cures by evaporation within 24 hours

Weight: 12.18 lbs. per gallon

VOC Level: "0"  grams/liter

Impact Resistance: 200+ psi front/160+ psi back

Shelf Life: up to 2 years (unopened) under appropriate storage conditions see MSDS

 

INSULATING WITH A SINGLE COAT NO THICKER THAN A BUSINESS CARD

 

RUSTVACCINE penetrates and locks in to encapsulate rust found in and around building structures. The danger associated with inhaling or ingesting these particles can be totally eliminated. RUSTVACCINE also has the ability to encapsulate substrates prone to mold and mildew.

 

   

©Copyright TDE Group SUPERTHERM Inc.

1999,2008

Phones : 

888-887-0144    -    928-443-0685

High Tech Corrosion - Lead - Asbestos Encapsulation
Navigate Our Site

DESCRIPTION:

 RUSTVACCINE  is a one-part polyurethane coating that contains no VOC's or known carcinogens. Upon curing, RUSTVACCINE provides a protective coating of superior adhesion, flexibility, abrasion- and impact-resistance. It is resistant to most chemical solvents and acid splash.

RUSTVACCINE can be used as a primer or a stand-alone coating. RUSTVACCINE can be tinted to any color and can serve as a finished top coat as well as a primer.

Can encapsulate other paints and other toxic materials. RUSTVACCINE can be applied directly over cleaned flash rust or most firmly bonded paints. In most cases, no near-white metal blasting is required.

TYPICAL USES:

As an encapsulant for paints, rust and other hazardous materials 

As a protective coating on metal, concrete, wood, etc. to add strength and prevent deterioration

As a single coat for bridges, oil platforms, roofs, etc. with minimal surface preparation

As a moisture barrier to stop water penetration, contamination, and mold/mildew

 

  

Product Application and Handling Tinting
APPLICATION METHODS:

NOTE: SURFACE MUST BE COMPLETELY DRY.

Surfaces should be clean, dry and sound; all dirt, salts, oil, tar, grease and film must be removed prior to application. Can be sprayed, brushed or rolled in 2 coats (20-30 minutes apart). Before using, stir thoroughly without creating a vortex to blend all metallic paste from the bottom. For specific instructions on surface preparation, mixing and application, refer to the application instructions for RUSTVACCINE.

 

SAFETY PRECAUTIONS:

 Do not use this product without first taking all appropriate safety measures to prevent property damage and injuries. These measures may include, without limitation: proper ventilation, use of proper lamps, wearing of protective clothing and masks, tenting, and proper separation of application areas.

 

IMPORTANT:
Metal structures should be primed with RUSTVACCINE before applying our insulation coatings

 

KEEP OUT OF REACH OF CHILDREN.

For more specific safety procedures, please refer to

the RUSTVACCINE Material Safety Data Sheet.

LIMITATION OF LIABILITY: The information contained in this data sheet is based upon tests that we believe to be accurate and is intended for guidance only. All recommendations or  suggestions relating to the use of the products  whether in technical documentation, or in response to a specific enquiry, or otherwise, are based on data which to the best of our knowledge is reliable. The products and information are designed for users having the requisite knowledge and industrial skills, and the end-user has the responsibility to determine the suitability of the product for its intended use.

SUPERTHERM Inc. has no control over either the quality of condition of the substrate, or the many factors affecting the use and application of the product.

Therefore, SUPERTHERM Inc. does not accept any liability arising from loss, injury, or damage resulting from such use or the contents of this data sheet (unless there are written agreements stating otherwise).

The information contained in this data sheet is subject to modification as a result of practical experience and continuous development.

 

RUSTVACCINE can be :

Tinted to any color

Marine Approvals for salt water/maritime use:

 

US Coast Guard *

ABS (American Bureau of Shipping) *

IMO (International Marine Organization) *

FM Factory Mutual Approval

E-108-00: spread of flame on pitched roofs (Class "A" non-combustible) *

Mildew Resistance - (ASTM D3273, 3274) *

Chemical Resistance (24 hours/12 reagents) *

Flexibility (Mandrel Bend : ASTM D522) - 1/8" *

Direct Impact Resistance (ASTM D2794) *

Adhesion (ASTM D3359, D4541)

Water Vapor Transmission (ASTM D1653) *

Surface Burning Characteristics (E84) *

Weathering (5000 hours) - *

Scrub Resistance (ASTM D2486) * 

(ASTM E1795)*

*All these tests scheduled for approval.

SAFETY PRECAUTIONS:

Do not use this product without first taking all appropriate safety measures to prevent property damage and injuries. These measures may include, without limitation: proper ventilation, use of proper lamps, wearing of protective clothing and masks, tenting, and proper separation of application areas.